Araştırma Makalesi

Determination of the Mass Attenuation Coefficient, Effective Atomic Number and Electron Density for Nano Manganese Hydroxyapatite by using 778-1457 keV Gamma Rays

Cilt: 5 Sayı: 2 2 Mart 2019
PDF İndir
EN

Determination of the Mass Attenuation Coefficient, Effective Atomic Number and Electron Density for Nano Manganese Hydroxyapatite by using 778-1457 keV Gamma Rays

Abstract

In this study, Nano Manganese substituted hydroxyapatite artificial bone powders (nMnHAp) have been investigated by means of mass attenuation coefficients, effective atomic numbers and electron densities experimentally. The samples were excited with using 778 keV, 964 keV, 1085 keV, 1111 keV, 1408 keV and 1457 keV gamma photons from Europium-152 (Eu152).The gamma photons from the source were counted by using gamma spectroscopy, a High Purity Germanium (HPGe) detector. The mass attenuation coefficients of the hydroxyapatites artificial bone powders (including hydroxyapatite without any substituted metal and real bone powder) were compared with each other. This study has been dealt with as a guide to medical field. Also the results have been evaluated in terms of the electron density and effectice atomic number.

Keywords

Kaynakça

  1. [1] S.G. Prasad, K. Parthasaradhi, W.D. Bloomer, Effective atomic numbers for photoabsorption in alloys in the energy region of absorption edges, Radiat Phys Chem, 53, 449-453 (1998).
  2. [2] D.K. Dubey, V. Tomar, Understanding the influence of structural hierarchy and its coupling with chemical environment on the strength of idealized tropocollagen-hydroxyapatite biomaterials, J Mech Phys Solids, 57, 1702-1717 (2009).
  3. [3] D.E. Wagner, K.M. Eisenmann, A.L. Nestor-Kalinoski, S.B. Bhaduri, A microwave-assisted solution combustion synthesis to produce europium-doped calcium phosphate nanowhiskers for bioimaging applications, Acta Biomater, 9, 8422-8432 (2013).
  4. [4] X. Wei, M.Z. Yates, Yttrium-Doped Hydroxyapatite Membranes with High Proton Conductivity, Chem Mater, 24,1738-1743 (2012).
  5. [5] Y. Watanabe, T. Ikoma, Y. Suetsugu, H. Yamada, K. Tamura, Y. Komatsu, J. Tanaka, Y. Moriyoshi, The densification of zeolite/apatite composites using a pulse electric current sintering method: A long-term assurance material for the disposal of radioactive waste, J Eur Ceram Soc, 26, 481-486 (2006).
  6. [6] J. Vamze, M. Pilmane, A. Skagers, Biocompatibility of pure and mixed hydroxyapatite and alpha-tricalcium phosphate implanted in rabbit bone, J Mater Sci-Mater M, 26 (2015).
  7. [7] C.T. Wong, W.W. Lu, W.K. Chan, K.M.C. Cheung, K.D.K. Lukl, D.S. Lu, A.B.M. Rabie, L.F. Deng, J.C.Y. Leong, In vivo cancellous bone remodeling on a strontium-containing hydroxyapatite (Sr-HA) bioactive cement, J Biomed Mater Res A, 68a, 513-521 (2004).
  8. [8] L. Nie, D. Chen, J. Fu, S.H. Yang, R.X. Hou, J.P. Suo, Macroporous biphasic calcium phosphate scaffolds reinforced by poly-L-lactic acid/hydroxyapatite nanocomposite coatings for bone regeneration, Biochem Eng J, 98, 29-37 (2015).

Ayrıntılar

Birincil Dil

İngilizce

Konular

Nükleer Bilimler

Bölüm

Araştırma Makalesi

Yazarlar

E. Cengiz
Türkiye

G. Apaydın
Türkiye

A. Tozar
Türkiye

İ. H. Karahan
Türkiye

Yayımlanma Tarihi

2 Mart 2019

Gönderilme Tarihi

20 Eylül 2018

Kabul Tarihi

1 Mart 2019

Yayımlandığı Sayı

Yıl 2018 Cilt: 5 Sayı: 2

Kaynak Göster

APA
Köksal, O., Cengiz, E., Apaydın, G., Tozar, A., & Karahan, İ. H. (2019). Determination of the Mass Attenuation Coefficient, Effective Atomic Number and Electron Density for Nano Manganese Hydroxyapatite by using 778-1457 keV Gamma Rays. Journal of Nuclear Sciences, 5(2), 24-29. https://doi.org/10.1501/nuclear_0000000044
AMA
1.Köksal O, Cengiz E, Apaydın G, Tozar A, Karahan İH. Determination of the Mass Attenuation Coefficient, Effective Atomic Number and Electron Density for Nano Manganese Hydroxyapatite by using 778-1457 keV Gamma Rays. Journal of Nuclear Sciences. 2019;5(2):24-29. doi:10.1501/nuclear_0000000044
Chicago
Köksal, O.k., E. Cengiz, G. Apaydın, A. Tozar, ve İ. H. Karahan. 2019. “Determination of the Mass Attenuation Coefficient, Effective Atomic Number and Electron Density for Nano Manganese Hydroxyapatite by using 778-1457 keV Gamma Rays”. Journal of Nuclear Sciences 5 (2): 24-29. https://doi.org/10.1501/nuclear_0000000044.
EndNote
Köksal O, Cengiz E, Apaydın G, Tozar A, Karahan İH (01 Mart 2019) Determination of the Mass Attenuation Coefficient, Effective Atomic Number and Electron Density for Nano Manganese Hydroxyapatite by using 778-1457 keV Gamma Rays. Journal of Nuclear Sciences 5 2 24–29.
IEEE
[1]O. Köksal, E. Cengiz, G. Apaydın, A. Tozar, ve İ. H. Karahan, “Determination of the Mass Attenuation Coefficient, Effective Atomic Number and Electron Density for Nano Manganese Hydroxyapatite by using 778-1457 keV Gamma Rays”, Journal of Nuclear Sciences, c. 5, sy 2, ss. 24–29, Mar. 2019, doi: 10.1501/nuclear_0000000044.
ISNAD
Köksal, O.k. - Cengiz, E. - Apaydın, G. - Tozar, A. - Karahan, İ. H. “Determination of the Mass Attenuation Coefficient, Effective Atomic Number and Electron Density for Nano Manganese Hydroxyapatite by using 778-1457 keV Gamma Rays”. Journal of Nuclear Sciences 5/2 (01 Mart 2019): 24-29. https://doi.org/10.1501/nuclear_0000000044.
JAMA
1.Köksal O, Cengiz E, Apaydın G, Tozar A, Karahan İH. Determination of the Mass Attenuation Coefficient, Effective Atomic Number and Electron Density for Nano Manganese Hydroxyapatite by using 778-1457 keV Gamma Rays. Journal of Nuclear Sciences. 2019;5:24–29.
MLA
Köksal, O.k., vd. “Determination of the Mass Attenuation Coefficient, Effective Atomic Number and Electron Density for Nano Manganese Hydroxyapatite by using 778-1457 keV Gamma Rays”. Journal of Nuclear Sciences, c. 5, sy 2, Mart 2019, ss. 24-29, doi:10.1501/nuclear_0000000044.
Vancouver
1.O.k. Köksal, E. Cengiz, G. Apaydın, A. Tozar, İ. H. Karahan. Determination of the Mass Attenuation Coefficient, Effective Atomic Number and Electron Density for Nano Manganese Hydroxyapatite by using 778-1457 keV Gamma Rays. Journal of Nuclear Sciences. 01 Mart 2019;5(2):24-9. doi:10.1501/nuclear_0000000044